What is building energy efficiency?
It is a building’s ability to provide comfort while using as little energy as possible. Two flats of the same size can use twice or half as much energy depending on how they are built and oriented. It mainly depends on three things:
- The building envelope: façades, roof, windows and floors. If they are poorly insulated or have thermal bridges, heat escapes in winter and gets in during summer.
- The design: orientation, shading, cross ventilation and use of daylight.
- The building services: heating, cooling, hot water and ventilation, and whether they use renewable energy such as heat pumps or solar panels.
The order matters: first reduce demand, so the building needs less energy, and then improve how that energy is produced. Done the other way round, you end up paying for a larger system than you need.
It helps you
- Reduce heating and cooling demand.
- Choose insulation, windows and building services on an informed basis.
- Make better use of daylight and sun on each orientation.
- Prioritise the improvements with the best cost-to-savings ratio.
- Prepare an energy retrofit or apply for grants.
How it is measured
The energy efficiency scale, from A to G
A building’s energy efficiency is expressed with the letters of the energy performance certificate (EPC), from A (most efficient) to G (least efficient). Two indicators are rated, each with its own letter:
- Non-renewable primary energy consumption, in kWh/m² per year: how much fossil-based energy the building uses per square metre.
- CO₂ emissions, in kg/m² per year.
Buildings constructed before there were thermal regulations (in Spain, the first date from 1979) usually have low ratings because they have no insulation. New buildings, on the other hand, must be nearly zero-energy buildings (NZEB), as the Spanish Building Code (CTE) now requires.
Certificate or study
Energy certificate or energy efficiency study: the difference
The energy performance certificate is mandatory for selling or letting and states the building’s current rating. An energy efficiency study is a design tool: it analyses why the building has that rating, compares alternatives and tells you which ones pay off before you invest.
If you only need the certificate, you can get a quote on our website.
What we study
Three approaches that can be combined
We tailor the scope to what you need, from a specific query to a full energy model. The study can be carried out at design stage, for a new build or a competition, or on an existing building before it is refurbished.
Climate and passive strategies
We analyse humidity, temperatures, ground temperature and other site data, and assess which passive strategies are most useful: orientation, shading, thermal mass or natural ventilation.
Solar radiation and daylighting
We check which façades and orientations capture the most energy and how many kWh/m² enter through each window, to decide on solar shading, the size of openings and the layout.
Energy demand and consumption
We size insulation and airtightness, propose building services and simulate the building’s energy performance over the year.
What you get
A clear report for data-driven decisions
You receive a report with a diagnosis of the current situation, the alternatives studied and the effect of each one on energy use, so you know what each design decision delivers or which improvements really pay off in a refurbishment.
If you then want to carry out the improvements, we can draw up the project, help you with grants and manage the works: energy retrofit, façade and roof refurbishment or home renovation.
A real case
Can Vilardell, Terrassa: 47 % less non-renewable energy
In the energy retrofit of three 1976 public housing blocks at Can Vilardell (commissioned by the Agència de l’Habitatge de Catalunya), the buildings had no insulation. With external wall insulation on the façades, roof insulation and new windows, block A went from:
- 287.6 to 152.9 kWh/m² per year of non-renewable primary energy (rating F to E): −47 %.
- 59.0 to 30.6 kg/m² per year of CO₂ emissions (rating E to D): −48 %.
- Façades losing 80 % less heat (U-value from 1.19 to 0.24 W/m²K).